| Kernel driver adm1275
 | |
| =====================
 | |
| 
 | |
| Supported chips:
 | |
|   * Analog Devices ADM1075
 | |
|     Prefix: 'adm1075'
 | |
|     Addresses scanned: -
 | |
|     Datasheet: www.analog.com/static/imported-files/data_sheets/ADM1075.pdf
 | |
|   * Analog Devices ADM1275
 | |
|     Prefix: 'adm1275'
 | |
|     Addresses scanned: -
 | |
|     Datasheet: www.analog.com/static/imported-files/data_sheets/ADM1275.pdf
 | |
|   * Analog Devices ADM1276
 | |
|     Prefix: 'adm1276'
 | |
|     Addresses scanned: -
 | |
|     Datasheet: www.analog.com/static/imported-files/data_sheets/ADM1276.pdf
 | |
| 
 | |
| Author: Guenter Roeck <guenter.roeck@ericsson.com>
 | |
| 
 | |
| 
 | |
| Description
 | |
| -----------
 | |
| 
 | |
| This driver supports hardware montoring for Analog Devices ADM1075, ADM1275,
 | |
| and ADM1276 Hot-Swap Controller and Digital Power Monitor.
 | |
| 
 | |
| ADM1075, ADM1275, and ADM1276 are hot-swap controllers that allow a circuit
 | |
| board to be removed from or inserted into a live backplane. They also feature
 | |
| current and voltage readback via an integrated 12-bit analog-to-digital
 | |
| converter (ADC), accessed using a PMBus interface.
 | |
| 
 | |
| The driver is a client driver to the core PMBus driver. Please see
 | |
| Documentation/hwmon/pmbus for details on PMBus client drivers.
 | |
| 
 | |
| 
 | |
| Usage Notes
 | |
| -----------
 | |
| 
 | |
| This driver does not auto-detect devices. You will have to instantiate the
 | |
| devices explicitly. Please see Documentation/i2c/instantiating-devices for
 | |
| details.
 | |
| 
 | |
| The ADM1075, unlike many other PMBus devices, does not support internal voltage
 | |
| or current scaling. Reported voltages, currents, and power are raw measurements,
 | |
| and will typically have to be scaled.
 | |
| 
 | |
| 
 | |
| Platform data support
 | |
| ---------------------
 | |
| 
 | |
| The driver supports standard PMBus driver platform data. Please see
 | |
| Documentation/hwmon/pmbus for details.
 | |
| 
 | |
| 
 | |
| Sysfs entries
 | |
| -------------
 | |
| 
 | |
| The following attributes are supported. Limits are read-write, history reset
 | |
| attributes are write-only, all other attributes are read-only.
 | |
| 
 | |
| in1_label		"vin1" or "vout1" depending on chip variant and
 | |
| 			configuration. On ADM1075, vout1 reports the voltage on
 | |
| 			the VAUX pin.
 | |
| in1_input		Measured voltage.
 | |
| in1_min			Minimum Voltage.
 | |
| in1_max			Maximum voltage.
 | |
| in1_min_alarm		Voltage low alarm.
 | |
| in1_max_alarm		Voltage high alarm.
 | |
| in1_highest		Historical maximum voltage.
 | |
| in1_reset_history	Write any value to reset history.
 | |
| 
 | |
| curr1_label		"iout1"
 | |
| curr1_input		Measured current.
 | |
| curr1_max		Maximum current.
 | |
| curr1_max_alarm		Current high alarm.
 | |
| curr1_lcrit		Critical minimum current. Depending on the chip
 | |
| 			configuration, either curr1_lcrit or curr1_crit is
 | |
| 			supported, but not both.
 | |
| curr1_lcrit_alarm	Critical current low alarm.
 | |
| curr1_crit		Critical maximum current. Depending on the chip
 | |
| 			configuration, either curr1_lcrit or curr1_crit is
 | |
| 			supported, but not both.
 | |
| curr1_crit_alarm	Critical current high alarm.
 | |
| curr1_highest		Historical maximum current.
 | |
| curr1_reset_history	Write any value to reset history.
 | |
| 
 | |
| power1_label		"pin1"
 | |
| power1_input		Input power.
 | |
| power1_reset_history	Write any value to reset history.
 | |
| 
 | |
| 			Power attributes are supported on ADM1075 and ADM1276
 | |
| 			only.
 | 