Qualcomm RPM Regulators
|
|
|
|
rpm-regulator-smd is a regulator driver which supports regulators inside of
|
|
PMICs which are controlled by the RPM processor. Communication with the RPM
|
|
processor takes place over SMD.
|
|
|
|
Required structure:
|
|
- RPM regulators must be described in two levels of devices nodes. The first
|
|
level describes the interface with the RPM. The second level describes
|
|
properties of one regulator framework interface (of potentially many) to
|
|
the regulator.
|
|
|
|
[First Level Nodes]
|
|
|
|
Required properties:
|
|
- compatible: Must be "qcom,rpm-smd-regulator-resource"
|
|
- qcom,resource-name: Resource name string for this regulator to be used in RPM
|
|
transactions. Length is 4 characters max.
|
|
- qcom,resource-id: Resource instance ID for this regulator to be used in RPM
|
|
transactions.
|
|
- qcom,regulator-type: Type of this regulator. Supported values are:
|
|
0 = LDO
|
|
1 = SMPS
|
|
2 = VS
|
|
3 = NCP
|
|
4 = Buck or Boost (BoB)
|
|
|
|
Optional properties:
|
|
- qcom,allow-atomic: Flag specifying if atomic access is allowed for this
|
|
regulator. Supported values are:
|
|
0 or not present = mutex locks used
|
|
1 = spinlocks used
|
|
- qcom,enable-time: Time in us to delay after enabling the regulator
|
|
- qcom,hpm-min-load: Load current in uA which corresponds to the minimum load
|
|
which requires the regulator to be in high power mode.
|
|
- qcom,apps-only: Flag which indicates that the regulator only has
|
|
consumers on the application processor. If this flag
|
|
is specified, then voltage and current updates are
|
|
only sent to the RPM if the regulator is enabled.
|
|
- qcom,always-wait-for-ack: Flag which indicates that the application
|
|
processor must wait for an ACK or a NACK from the RPM
|
|
for every request sent for this regulator including
|
|
those which are for a strictly lower power state.
|
|
|
|
[Second Level Nodes]
|
|
|
|
Required properties:
|
|
- compatible: Must be "qcom,rpm-smd-regulator"
|
|
- regulator-name: A string used as a descriptive name for regulator outputs
|
|
- qcom,set: Specifies which sets that requests made with this
|
|
regulator interface should be sent to. Regulator
|
|
requests sent in the active set take effect immediately.
|
|
Requests sent in the sleep set take effect when the Apps
|
|
processor transitions into RPM assisted power collapse.
|
|
Supported values are:
|
|
1 = Active set only
|
|
2 = Sleep set only
|
|
3 = Both active and sleep sets
|
|
|
|
|
|
|
|
Optional properties:
|
|
- parent-supply: phandle to the parent supply/regulator node
|
|
- qcom,system-load: Load in uA present on regulator that is not
|
|
captured by any consumer request
|
|
- qcom,use-voltage-corner: Flag that signifies if regulator_set_voltage
|
|
calls should modify the corner parameter instead
|
|
of the voltage parameter. When used, voltages
|
|
specified inside of the regulator framework
|
|
represent corners that have been incremented by
|
|
1. This value shift is necessary to work around
|
|
limitations in the regulator framework which
|
|
treat 0 uV as an error.
|
|
- qcom,use-voltage-floor-corner: Flag that signifies if regulator_set_voltage
|
|
calls should modify the floor corner parameter
|
|
instead of the voltage parameter. When used,
|
|
voltages specified inside of the regulator
|
|
framework represent corners that have been
|
|
incremented by 1. The properties
|
|
qcom,use-voltage-corner and
|
|
qcom,use-voltage-floor-corner are mutually
|
|
exclusive. Only one may be specified for a
|
|
given regulator.
|
|
- qcom,use-voltage-level: Flag that signifies if regulator_set_voltage
|
|
calls should modify the level parameter instead
|
|
of the voltage parameter.
|
|
- qcom,use-voltage-floor-level: Flag that signifies if regulator_set_voltage
|
|
calls should modify the floor level parameter
|
|
instead of the voltage parameter.
|
|
The properties qcom,use-voltage-level and
|
|
qcom,use-voltage-floor-level are mutually
|
|
exclusive. Only one may be specified for a
|
|
given regulator.
|
|
- qcom,use-pin-ctrl-voltage1: Flag which indicates that updates to voltage
|
|
should be sent to the pin control voltage 1
|
|
parameter. Only one pin may be specified per
|
|
regulator. This property only applies to BoB
|
|
type regulators.
|
|
- qcom,use-pin-ctrl-voltage2: Flag which indicates that updates to voltage
|
|
should be sent to the pin control voltage 2
|
|
parameter. Only one pin may be specified per
|
|
regulator. This property only applies to BoB
|
|
type regulators.
|
|
- qcom,use-pin-ctrl-voltage3: Flag which indicates that updates to voltage
|
|
should be sent to the pin control voltage 3
|
|
parameter. Only one pin may be specified per
|
|
regulator. This property only applies to BoB
|
|
type regulators.
|
|
- qcom,always-send-voltage: Flag which indicates that updates to the
|
|
voltage, voltage corner or voltage level set
|
|
point should always be sent immediately to the
|
|
RPM. If this flag is not specified, then
|
|
voltage set point updates are only sent if the
|
|
given regulator has also been enabled by a
|
|
Linux consumer.
|
|
- qcom,always-send-current: Flag which indicates that updates to the load
|
|
current should always be sent immediately to the
|
|
RPM. If this flag is not specified, then load
|
|
current updates are only sent if the given
|
|
regulator has also been enabled by a Linux
|
|
consumer.
|
|
- qcom,send-defaults: Boolean flag which indicates that the initial
|
|
parameter values should be sent to the RPM
|
|
before consumers make their own requests. If
|
|
this flag is not specified, then initial
|
|
parameters values will only be sent after some
|
|
consumer makes a request.
|
|
- qcom,enable-with-pin-ctrl: Double in which the first element corresponds to
|
|
the pin control enable parameter value to send
|
|
when all consumers have requested the regulator
|
|
to be disabled. The second element corresponds
|
|
to the pin control enable parameter value to
|
|
send when any consumer has requested the
|
|
regulator to be enabled. Each element supports
|
|
the same set of values as the
|
|
qcom,init-pin-ctrl-enable property listed below.
|
|
|
|
The following properties specify initial values for parameters to be sent to the
|
|
RPM in regulator requests.
|
|
- qcom,init-enable: 0 = regulator disabled
|
|
1 = regulator enabled
|
|
- qcom,init-voltage: Voltage in uV
|
|
- qcom,init-current: Current in mA
|
|
- qcom,init-ldo-mode: Operating mode to be used with LDO regulators
|
|
Supported values are:
|
|
0 = mode determined by current requests
|
|
1 = force HPM (NPM)
|
|
- qcom,init-smps-mode: Operating mode to be used with SMPS regulators
|
|
Supported values are:
|
|
0 = auto; hardware determines mode
|
|
1 = mode determined by current requests
|
|
2 = force HPM (PWM)
|
|
- qcom,init-bob-mode: Operating mode to be used with BoB regulators
|
|
Supported values are:
|
|
0 = pass; use priority order
|
|
1 = force PFM
|
|
2 = auto; hardware determines mode
|
|
3 = force PWM
|
|
- qcom,init-pin-ctrl-enable: Bit mask specifying which hardware pins should be
|
|
used to enable the regulator, if any; supported
|
|
bits are:
|
|
0 = ignore all hardware enable signals
|
|
BIT(0) = follow HW0_EN signal
|
|
BIT(1) = follow HW1_EN signal
|
|
BIT(2) = follow HW2_EN signal
|
|
BIT(3) = follow HW3_EN signal
|
|
- qcom,init-pin-ctrl-mode: Bit mask specifying which hardware pins should be
|
|
used to force the regulator into high power
|
|
mode, if any. Supported bits are:
|
|
0 = ignore all hardware enable signals
|
|
BIT(0) = follow HW0_EN signal
|
|
BIT(1) = follow HW1_EN signal
|
|
BIT(2) = follow HW2_EN signal
|
|
BIT(3) = follow HW3_EN signal
|
|
BIT(4) = follow PMIC awake state
|
|
- qcom,init-pin-ctrl-voltage1: Minimum voltage in micro-volts to use while pin
|
|
control 1 is enabled. This property only
|
|
applies to BoB type regulators.
|
|
- qcom,init-pin-ctrl-voltage2: Minimum voltage in micro-volts to use while pin
|
|
control 2 is enabled. This property only
|
|
applies to BoB type regulators.
|
|
- qcom,init-pin-ctrl-voltage3: Minimum voltage in micro-volts to use while pin
|
|
control 3 is enabled. This property only
|
|
applies to BoB type regulators.
|
|
- qcom,init-frequency: Switching frequency divisor for SMPS regulators.
|
|
Supported values are n = 0 to 31 where
|
|
freq = 19.2 MHz / (n + 1).
|
|
- qcom,init-head-room: Voltage head room in mV required for the
|
|
regulator. This head room value should be used
|
|
in situations where the device connected to the
|
|
output of the regulator has low noise tolerance.
|
|
Note that the RPM independently enforces a
|
|
safety head room value for subregulated LDOs
|
|
which is sufficient to account for LDO drop-out
|
|
voltage.
|
|
- qcom,init-quiet-mode: Specify that quiet mode is needed for an SMPS
|
|
regulator in order to have lower output noise.
|
|
Supported values are:
|
|
0 = No quiet mode
|
|
1 = Quiet mode
|
|
2 = Super quiet mode
|
|
- qcom,init-freq-reason: Consumer requiring specified frequency for an
|
|
SMPS regulator. Supported values are:
|
|
0 = None
|
|
1 = Bluetooth
|
|
2 = GPS
|
|
4 = WLAN
|
|
8 = WAN
|
|
- qcom,init-voltage-corner: Performance corner to use in order to determine
|
|
voltage set point. This value corresponds to
|
|
the actual value that will be sent and is not
|
|
incremented by 1 like the values used inside of
|
|
the regulator framework. The meaning of corner
|
|
values is set by the RPM. It is possible that
|
|
different regulators on a given platform or
|
|
similar regulators on different platforms will
|
|
utilize different corner values. These are
|
|
corner values supported on MSM8974 for PMIC
|
|
PM8841 SMPS 2 (VDD_Dig); nominal voltages for
|
|
these corners are also shown:
|
|
0 = None (don't care)
|
|
1 = Retention (0.5000 V)
|
|
2 = SVS Krait (0.7250 V)
|
|
3 = SVS SOC (0.8125 V)
|
|
4 = Normal (0.9000 V)
|
|
5 = Turbo (0.9875 V)
|
|
6 = Super Turbo (1.0500 V)
|
|
- qcom,init-disallow-bypass: Specify that bypass mode should not be used for a
|
|
given LDO regulator. When in bypass mode, an
|
|
LDO performs no regulation and acts as a simple
|
|
switch. The RPM can utilize this mode for an
|
|
LDO that is subregulated from an SMPS when it is
|
|
possible to reduce the SMPS voltage to the
|
|
desired LDO output level. Bypass mode may be
|
|
disallowed if lower LDO output noise is
|
|
required. Supported values are:
|
|
0 = Allow RPM to utilize LDO bypass mode
|
|
if possible
|
|
1 = Disallow LDO bypass mode
|
|
- qcom,init-voltage-floor-corner: Minimum performance corner to use if any
|
|
processor in the system is awake. This property
|
|
supports the same values as
|
|
qcom,init-voltage-corner.
|
|
- qcom,init-voltage-level: Performance level to use in order to determine
|
|
voltage set point. The meaning of level
|
|
values is set by the RPM. It is possible that
|
|
different regulators on a given platform or
|
|
similar regulators on different platforms will
|
|
utilize different level values. These are
|
|
level values supported on MSM8952 for PMIC
|
|
PM8952 SMPS 2 (VDD_Dig); nominal voltages for
|
|
these level are also shown:
|
|
16 = Retention (0.5000 V)
|
|
128 = SVS (1.0500 V)
|
|
192 = SVS+ (1.1550 V)
|
|
256 = Normal (1.2250 V)
|
|
320 = Normal+ (1.2875 V)
|
|
384 = Turbo (1.3500 V)
|
|
- qcom,init-voltage-floor-level: Minimum performance level to use if any
|
|
processor in the system is awake. This property
|
|
supports the same values as
|
|
qcom,init-voltage-level.
|
|
|
|
All properties specified within the core regulator framework can also be used in
|
|
second level nodes. These bindings can be found in:
|
|
Documentation/devicetree/bindings/regulator/regulator.txt.
|
|
|
|
Examples:
|
|
|
|
rpm-regulator-smpb1 {
|
|
qcom,resource-name = "smpb";
|
|
qcom,resource-id = <1>;
|
|
qcom,regulator-type = <1>;
|
|
qcom,hpm-min-load = <100000>;
|
|
compatible = "qcom,rpm-smd-regulator-resource";
|
|
status = "disabled";
|
|
|
|
pm8841_s1: regulator-s1 {
|
|
regulator-name = "8841_s1";
|
|
qcom,set = <3>;
|
|
regulator-min-microvolt = <900000>;
|
|
regulator-max-microvolt = <1150000>;
|
|
qcom,init-voltage = <1150000>;
|
|
compatible = "qcom,rpm-smd-regulator";
|
|
};
|
|
pm8841_s1_ao: regulator-s1-ao {
|
|
regulator-name = "8841_s1_ao";
|
|
qcom,set = <1>;
|
|
regulator-min-microvolt = <900000>;
|
|
regulator-max-microvolt = <1150000>;
|
|
compatible = "qcom,rpm-smd-regulator";
|
|
};
|
|
pm8841_s1_corner: regulator-s1-corner {
|
|
regulator-name = "8841_s1_corner";
|
|
qcom,set = <3>;
|
|
regulator-min-microvolt = <1>;
|
|
regulator-max-microvolt = <6>;
|
|
qcom,init-voltage-corner = <3>;
|
|
qcom,use-voltage-corner;
|
|
compatible = "qcom,rpm-smd-regulator";
|
|
};
|
|
};
|
|
|
|
rpm-regulator-ldoa2 {
|
|
qcom,resource-name = "ldoa";
|
|
qcom,resource-id = <2>;
|
|
qcom,regulator-type = <0>;
|
|
qcom,hpm-min-load = <10000>;
|
|
compatible = "qcom,rpm-smd-regulator-resource";
|
|
|
|
regulator-l2 {
|
|
compatible = "qcom,rpm-smd-regulator";
|
|
regulator-name = "8941_l2";
|
|
qcom,set = <3>;
|
|
regulator-min-microvolt = <1225000>;
|
|
regulator-max-microvolt = <1225000>;
|
|
qcom,init-voltage = <1225000>;
|
|
};
|
|
regulator-l2-pin-ctrl {
|
|
compatible = "qcom,rpm-smd-regulator";
|
|
regulator-name = "8941_l2_pin_ctrl";
|
|
qcom,set = <3>;
|
|
regulator-min-microvolt = <1225000>;
|
|
regulator-max-microvolt = <1225000>;
|
|
qcom,init-voltage = <1225000>;
|
|
qcom,enable-with-pin-ctrl = <0 1>;
|
|
};
|
|
};
|