M7350/kernel/Documentation/devicetree/bindings/regulator/rpm-smd-regulator.txt

329 lines
13 KiB
Plaintext
Raw Normal View History

2024-09-09 08:52:07 +00:00
Qualcomm RPM Regulators
rpm-regulator-smd is a regulator driver which supports regulators inside of
PMICs which are controlled by the RPM processor. Communication with the RPM
processor takes place over SMD.
Required structure:
- RPM regulators must be described in two levels of devices nodes. The first
level describes the interface with the RPM. The second level describes
properties of one regulator framework interface (of potentially many) to
the regulator.
[First Level Nodes]
Required properties:
2024-09-09 08:57:42 +00:00
- compatible: Must be "qcom,rpm-smd-regulator-resource"
2024-09-09 08:52:07 +00:00
- qcom,resource-name: Resource name string for this regulator to be used in RPM
transactions. Length is 4 characters max.
- qcom,resource-id: Resource instance ID for this regulator to be used in RPM
transactions.
- qcom,regulator-type: Type of this regulator. Supported values are:
0 = LDO
1 = SMPS
2 = VS
3 = NCP
2024-09-09 08:57:42 +00:00
4 = Buck or Boost (BoB)
2024-09-09 08:52:07 +00:00
Optional properties:
- qcom,allow-atomic: Flag specifying if atomic access is allowed for this
regulator. Supported values are:
0 or not present = mutex locks used
1 = spinlocks used
- qcom,enable-time: Time in us to delay after enabling the regulator
- qcom,hpm-min-load: Load current in uA which corresponds to the minimum load
which requires the regulator to be in high power mode.
2024-09-09 08:57:42 +00:00
- qcom,apps-only: Flag which indicates that the regulator only has
consumers on the application processor. If this flag
is specified, then voltage and current updates are
only sent to the RPM if the regulator is enabled.
- qcom,always-wait-for-ack: Flag which indicates that the application
processor must wait for an ACK or a NACK from the RPM
for every request sent for this regulator including
those which are for a strictly lower power state.
2024-09-09 08:52:07 +00:00
[Second Level Nodes]
Required properties:
2024-09-09 08:57:42 +00:00
- compatible: Must be "qcom,rpm-smd-regulator"
2024-09-09 08:52:07 +00:00
- regulator-name: A string used as a descriptive name for regulator outputs
- qcom,set: Specifies which sets that requests made with this
regulator interface should be sent to. Regulator
requests sent in the active set take effect immediately.
Requests sent in the sleep set take effect when the Apps
processor transitions into RPM assisted power collapse.
Supported values are:
1 = Active set only
2 = Sleep set only
3 = Both active and sleep sets
Optional properties:
- parent-supply: phandle to the parent supply/regulator node
- qcom,system-load: Load in uA present on regulator that is not
captured by any consumer request
- qcom,use-voltage-corner: Flag that signifies if regulator_set_voltage
calls should modify the corner parameter instead
of the voltage parameter. When used, voltages
specified inside of the regulator framework
represent corners that have been incremented by
1. This value shift is necessary to work around
limitations in the regulator framework which
treat 0 uV as an error.
- qcom,use-voltage-floor-corner: Flag that signifies if regulator_set_voltage
calls should modify the floor corner parameter
instead of the voltage parameter. When used,
voltages specified inside of the regulator
framework represent corners that have been
incremented by 1. The properties
qcom,use-voltage-corner and
qcom,use-voltage-floor-corner are mutually
exclusive. Only one may be specified for a
given regulator.
2024-09-09 08:57:42 +00:00
- qcom,use-voltage-level: Flag that signifies if regulator_set_voltage
calls should modify the level parameter instead
of the voltage parameter.
- qcom,use-voltage-floor-level: Flag that signifies if regulator_set_voltage
calls should modify the floor level parameter
instead of the voltage parameter.
The properties qcom,use-voltage-level and
qcom,use-voltage-floor-level are mutually
exclusive. Only one may be specified for a
given regulator.
- qcom,use-pin-ctrl-voltage1: Flag which indicates that updates to voltage
should be sent to the pin control voltage 1
parameter. Only one pin may be specified per
regulator. This property only applies to BoB
type regulators.
- qcom,use-pin-ctrl-voltage2: Flag which indicates that updates to voltage
should be sent to the pin control voltage 2
parameter. Only one pin may be specified per
regulator. This property only applies to BoB
type regulators.
- qcom,use-pin-ctrl-voltage3: Flag which indicates that updates to voltage
should be sent to the pin control voltage 3
parameter. Only one pin may be specified per
regulator. This property only applies to BoB
type regulators.
- qcom,always-send-voltage: Flag which indicates that updates to the
voltage, voltage corner or voltage level set
point should always be sent immediately to the
RPM. If this flag is not specified, then
voltage set point updates are only sent if the
given regulator has also been enabled by a
Linux consumer.
2024-09-09 08:52:07 +00:00
- qcom,always-send-current: Flag which indicates that updates to the load
current should always be sent immediately to the
RPM. If this flag is not specified, then load
current updates are only sent if the given
regulator has also been enabled by a Linux
consumer.
2024-09-09 08:57:42 +00:00
- qcom,send-defaults: Boolean flag which indicates that the initial
parameter values should be sent to the RPM
before consumers make their own requests. If
this flag is not specified, then initial
parameters values will only be sent after some
consumer makes a request.
- qcom,enable-with-pin-ctrl: Double in which the first element corresponds to
the pin control enable parameter value to send
when all consumers have requested the regulator
to be disabled. The second element corresponds
to the pin control enable parameter value to
send when any consumer has requested the
regulator to be enabled. Each element supports
the same set of values as the
qcom,init-pin-ctrl-enable property listed below.
2024-09-09 08:52:07 +00:00
The following properties specify initial values for parameters to be sent to the
RPM in regulator requests.
- qcom,init-enable: 0 = regulator disabled
1 = regulator enabled
- qcom,init-voltage: Voltage in uV
- qcom,init-current: Current in mA
- qcom,init-ldo-mode: Operating mode to be used with LDO regulators
Supported values are:
0 = mode determined by current requests
1 = force HPM (NPM)
- qcom,init-smps-mode: Operating mode to be used with SMPS regulators
Supported values are:
0 = auto; hardware determines mode
1 = mode determined by current requests
2 = force HPM (PWM)
2024-09-09 08:57:42 +00:00
- qcom,init-bob-mode: Operating mode to be used with BoB regulators
Supported values are:
0 = pass; use priority order
1 = force PFM
2 = auto; hardware determines mode
3 = force PWM
2024-09-09 08:52:07 +00:00
- qcom,init-pin-ctrl-enable: Bit mask specifying which hardware pins should be
used to enable the regulator, if any; supported
bits are:
0 = ignore all hardware enable signals
BIT(0) = follow HW0_EN signal
BIT(1) = follow HW1_EN signal
BIT(2) = follow HW2_EN signal
BIT(3) = follow HW3_EN signal
- qcom,init-pin-ctrl-mode: Bit mask specifying which hardware pins should be
used to force the regulator into high power
mode, if any. Supported bits are:
0 = ignore all hardware enable signals
BIT(0) = follow HW0_EN signal
BIT(1) = follow HW1_EN signal
BIT(2) = follow HW2_EN signal
BIT(3) = follow HW3_EN signal
BIT(4) = follow PMIC awake state
2024-09-09 08:57:42 +00:00
- qcom,init-pin-ctrl-voltage1: Minimum voltage in micro-volts to use while pin
control 1 is enabled. This property only
applies to BoB type regulators.
- qcom,init-pin-ctrl-voltage2: Minimum voltage in micro-volts to use while pin
control 2 is enabled. This property only
applies to BoB type regulators.
- qcom,init-pin-ctrl-voltage3: Minimum voltage in micro-volts to use while pin
control 3 is enabled. This property only
applies to BoB type regulators.
2024-09-09 08:52:07 +00:00
- qcom,init-frequency: Switching frequency divisor for SMPS regulators.
Supported values are n = 0 to 31 where
freq = 19.2 MHz / (n + 1).
- qcom,init-head-room: Voltage head room in mV required for the
regulator. This head room value should be used
in situations where the device connected to the
output of the regulator has low noise tolerance.
Note that the RPM independently enforces a
safety head room value for subregulated LDOs
which is sufficient to account for LDO drop-out
voltage.
- qcom,init-quiet-mode: Specify that quiet mode is needed for an SMPS
regulator in order to have lower output noise.
Supported values are:
0 = No quiet mode
1 = Quiet mode
2 = Super quiet mode
- qcom,init-freq-reason: Consumer requiring specified frequency for an
SMPS regulator. Supported values are:
0 = None
1 = Bluetooth
2 = GPS
4 = WLAN
8 = WAN
- qcom,init-voltage-corner: Performance corner to use in order to determine
voltage set point. This value corresponds to
the actual value that will be sent and is not
incremented by 1 like the values used inside of
the regulator framework. The meaning of corner
values is set by the RPM. It is possible that
different regulators on a given platform or
similar regulators on different platforms will
utilize different corner values. These are
corner values supported on MSM8974 for PMIC
PM8841 SMPS 2 (VDD_Dig); nominal voltages for
these corners are also shown:
0 = None (don't care)
1 = Retention (0.5000 V)
2 = SVS Krait (0.7250 V)
3 = SVS SOC (0.8125 V)
4 = Normal (0.9000 V)
5 = Turbo (0.9875 V)
6 = Super Turbo (1.0500 V)
- qcom,init-disallow-bypass: Specify that bypass mode should not be used for a
given LDO regulator. When in bypass mode, an
LDO performs no regulation and acts as a simple
switch. The RPM can utilize this mode for an
LDO that is subregulated from an SMPS when it is
possible to reduce the SMPS voltage to the
desired LDO output level. Bypass mode may be
disallowed if lower LDO output noise is
required. Supported values are:
0 = Allow RPM to utilize LDO bypass mode
if possible
1 = Disallow LDO bypass mode
- qcom,init-voltage-floor-corner: Minimum performance corner to use if any
processor in the system is awake. This property
supports the same values as
qcom,init-voltage-corner.
2024-09-09 08:57:42 +00:00
- qcom,init-voltage-level: Performance level to use in order to determine
voltage set point. The meaning of level
values is set by the RPM. It is possible that
different regulators on a given platform or
similar regulators on different platforms will
utilize different level values. These are
level values supported on MSM8952 for PMIC
PM8952 SMPS 2 (VDD_Dig); nominal voltages for
these level are also shown:
16 = Retention (0.5000 V)
128 = SVS (1.0500 V)
192 = SVS+ (1.1550 V)
256 = Normal (1.2250 V)
320 = Normal+ (1.2875 V)
384 = Turbo (1.3500 V)
- qcom,init-voltage-floor-level: Minimum performance level to use if any
processor in the system is awake. This property
supports the same values as
qcom,init-voltage-level.
2024-09-09 08:52:07 +00:00
All properties specified within the core regulator framework can also be used in
second level nodes. These bindings can be found in:
Documentation/devicetree/bindings/regulator/regulator.txt.
2024-09-09 08:57:42 +00:00
Examples:
2024-09-09 08:52:07 +00:00
rpm-regulator-smpb1 {
qcom,resource-name = "smpb";
qcom,resource-id = <1>;
qcom,regulator-type = <1>;
qcom,hpm-min-load = <100000>;
2024-09-09 08:57:42 +00:00
compatible = "qcom,rpm-smd-regulator-resource";
2024-09-09 08:52:07 +00:00
status = "disabled";
pm8841_s1: regulator-s1 {
regulator-name = "8841_s1";
qcom,set = <3>;
regulator-min-microvolt = <900000>;
regulator-max-microvolt = <1150000>;
qcom,init-voltage = <1150000>;
2024-09-09 08:57:42 +00:00
compatible = "qcom,rpm-smd-regulator";
2024-09-09 08:52:07 +00:00
};
pm8841_s1_ao: regulator-s1-ao {
regulator-name = "8841_s1_ao";
qcom,set = <1>;
regulator-min-microvolt = <900000>;
regulator-max-microvolt = <1150000>;
2024-09-09 08:57:42 +00:00
compatible = "qcom,rpm-smd-regulator";
2024-09-09 08:52:07 +00:00
};
pm8841_s1_corner: regulator-s1-corner {
regulator-name = "8841_s1_corner";
qcom,set = <3>;
regulator-min-microvolt = <1>;
regulator-max-microvolt = <6>;
qcom,init-voltage-corner = <3>;
qcom,use-voltage-corner;
2024-09-09 08:57:42 +00:00
compatible = "qcom,rpm-smd-regulator";
};
};
rpm-regulator-ldoa2 {
qcom,resource-name = "ldoa";
qcom,resource-id = <2>;
qcom,regulator-type = <0>;
qcom,hpm-min-load = <10000>;
compatible = "qcom,rpm-smd-regulator-resource";
regulator-l2 {
compatible = "qcom,rpm-smd-regulator";
regulator-name = "8941_l2";
qcom,set = <3>;
regulator-min-microvolt = <1225000>;
regulator-max-microvolt = <1225000>;
qcom,init-voltage = <1225000>;
};
regulator-l2-pin-ctrl {
compatible = "qcom,rpm-smd-regulator";
regulator-name = "8941_l2_pin_ctrl";
qcom,set = <3>;
regulator-min-microvolt = <1225000>;
regulator-max-microvolt = <1225000>;
qcom,init-voltage = <1225000>;
qcom,enable-with-pin-ctrl = <0 1>;
2024-09-09 08:52:07 +00:00
};
};