Kernel driver ds1621
 | 
						|
====================
 | 
						|
 | 
						|
Supported chips:
 | 
						|
  * Dallas Semiconductor / Maxim Integrated DS1621
 | 
						|
    Prefix: 'ds1621'
 | 
						|
    Addresses scanned: none
 | 
						|
    Datasheet: Publicly available from www.maximintegrated.com
 | 
						|
 | 
						|
  * Dallas Semiconductor DS1625
 | 
						|
    Prefix: 'ds1625'
 | 
						|
    Addresses scanned: none
 | 
						|
    Datasheet: Publicly available from www.datasheetarchive.com
 | 
						|
 | 
						|
  * Maxim Integrated DS1631
 | 
						|
    Prefix: 'ds1631'
 | 
						|
    Addresses scanned: none
 | 
						|
    Datasheet: Publicly available from www.maximintegrated.com
 | 
						|
 | 
						|
  * Maxim Integrated DS1721
 | 
						|
    Prefix: 'ds1721'
 | 
						|
    Addresses scanned: none
 | 
						|
    Datasheet: Publicly available from www.maximintegrated.com
 | 
						|
 | 
						|
  * Maxim Integrated DS1731
 | 
						|
    Prefix: 'ds1731'
 | 
						|
    Addresses scanned: none
 | 
						|
    Datasheet: Publicly available from www.maximintegrated.com
 | 
						|
 | 
						|
Authors:
 | 
						|
        Christian W. Zuckschwerdt <zany@triq.net>
 | 
						|
        valuable contributions by Jan M. Sendler <sendler@sendler.de>
 | 
						|
        ported to 2.6 by Aurelien Jarno <aurelien@aurel32.net>
 | 
						|
        with the help of Jean Delvare <jdelvare@suse.de>
 | 
						|
 | 
						|
Module Parameters
 | 
						|
------------------
 | 
						|
 | 
						|
* polarity int
 | 
						|
  Output's polarity: 0 = active high, 1 = active low
 | 
						|
 | 
						|
Description
 | 
						|
-----------
 | 
						|
 | 
						|
The DS1621 is a (one instance) digital thermometer and thermostat. It has
 | 
						|
both high and low temperature limits which can be user defined (i.e.
 | 
						|
programmed into non-volatile on-chip registers). Temperature range is -55
 | 
						|
degree Celsius to +125 in 0.5 increments. You may convert this into a
 | 
						|
Fahrenheit range of -67 to +257 degrees with 0.9 steps. If polarity
 | 
						|
parameter is not provided, original value is used.
 | 
						|
 | 
						|
As for the thermostat, behavior can also be programmed using the polarity
 | 
						|
toggle. On the one hand ("heater"), the thermostat output of the chip,
 | 
						|
Tout, will trigger when the low limit temperature is met or underrun and
 | 
						|
stays high until the high limit is met or exceeded. On the other hand
 | 
						|
("cooler"), vice versa. That way "heater" equals "active low", whereas
 | 
						|
"conditioner" equals "active high". Please note that the DS1621 data sheet
 | 
						|
is somewhat misleading in this point since setting the polarity bit does
 | 
						|
not simply invert Tout.
 | 
						|
 | 
						|
A second thing is that, during extensive testing, Tout showed a tolerance
 | 
						|
of up to +/- 0.5 degrees even when compared against precise temperature
 | 
						|
readings. Be sure to have a high vs. low temperature limit gap of al least
 | 
						|
1.0 degree Celsius to avoid Tout "bouncing", though!
 | 
						|
 | 
						|
The alarm bits are set when the high or low limits are met or exceeded and
 | 
						|
are reset by the module as soon as the respective temperature ranges are
 | 
						|
left.
 | 
						|
 | 
						|
The alarm registers are in no way suitable to find out about the actual
 | 
						|
status of Tout. They will only tell you about its history, whether or not
 | 
						|
any of the limits have ever been met or exceeded since last power-up or
 | 
						|
reset. Be aware: When testing, it showed that the status of Tout can change
 | 
						|
with neither of the alarms set.
 | 
						|
 | 
						|
Since there is no version or vendor identification register, there is
 | 
						|
no unique identification for these devices. Therefore, explicit device
 | 
						|
instantiation is required for correct device identification and functionality
 | 
						|
(one device per address in this address range: 0x48..0x4f).
 | 
						|
 | 
						|
The DS1625 is pin compatible and functionally equivalent with the DS1621,
 | 
						|
but the DS1621 is meant to replace it. The DS1631, DS1721, and DS1731 are
 | 
						|
also pin compatible with the DS1621 and provide multi-resolution support.
 | 
						|
 | 
						|
Additionally, the DS1721 data sheet says the temperature flags (THF and TLF)
 | 
						|
are used internally, however, these flags do get set and cleared as the actual
 | 
						|
temperature crosses the min or max settings (which by default are set to 75
 | 
						|
and 80 degrees respectively).
 | 
						|
 | 
						|
Temperature Conversion:
 | 
						|
-----------------------
 | 
						|
DS1621 - 750ms (older devices may take up to 1000ms)
 | 
						|
DS1625 - 500ms
 | 
						|
DS1631 - 93ms..750ms for 9..12 bits resolution, respectively.
 | 
						|
DS1721 - 93ms..750ms for 9..12 bits resolution, respectively.
 | 
						|
DS1731 - 93ms..750ms for 9..12 bits resolution, respectively.
 | 
						|
 | 
						|
Note:
 | 
						|
On the DS1621, internal access to non-volatile registers may last for 10ms
 | 
						|
or less (unverified on the other devices).
 | 
						|
 | 
						|
Temperature Accuracy:
 | 
						|
---------------------
 | 
						|
DS1621: +/- 0.5 degree Celsius (from 0 to +70 degrees)
 | 
						|
DS1625: +/- 0.5 degree Celsius (from 0 to +70 degrees)
 | 
						|
DS1631: +/- 0.5 degree Celsius (from 0 to +70 degrees)
 | 
						|
DS1721: +/- 1.0 degree Celsius (from -10 to +85 degrees)
 | 
						|
DS1731: +/- 1.0 degree Celsius (from -10 to +85 degrees)
 | 
						|
 | 
						|
Note:
 | 
						|
Please refer to the device datasheets for accuracy at other temperatures.
 | 
						|
 | 
						|
Temperature Resolution:
 | 
						|
-----------------------
 | 
						|
As mentioned above, the DS1631, DS1721, and DS1731 provide multi-resolution
 | 
						|
support, which is achieved via the R0 and R1 config register bits, where:
 | 
						|
 | 
						|
R0..R1
 | 
						|
------
 | 
						|
 0  0 => 9 bits, 0.5 degrees Celcius
 | 
						|
 1  0 => 10 bits, 0.25 degrees Celcius
 | 
						|
 0  1 => 11 bits, 0.125 degrees Celcius
 | 
						|
 1  1 => 12 bits, 0.0625 degrees Celcius
 | 
						|
 | 
						|
Note:
 | 
						|
At initial device power-on, the default resolution is set to 12-bits.
 | 
						|
 | 
						|
The resolution mode for the DS1631, DS1721, or DS1731 can be changed from
 | 
						|
userspace, via the device 'update_interval' sysfs attribute. This attribute
 | 
						|
will normalize the range of input values to the device maximum resolution
 | 
						|
values defined in the datasheet as follows:
 | 
						|
 | 
						|
Resolution    Conversion Time    Input Range
 | 
						|
 (C/LSB)       (msec)             (msec)
 | 
						|
------------------------------------------------
 | 
						|
0.5             93.75              0....94
 | 
						|
0.25            187.5              95...187
 | 
						|
0.125           375                188..375
 | 
						|
0.0625          750                376..infinity
 | 
						|
------------------------------------------------
 | 
						|
 | 
						|
The following examples show how the 'update_interval' attribute can be
 | 
						|
used to change the conversion time:
 | 
						|
 | 
						|
$ cat update_interval
 | 
						|
750
 | 
						|
$ cat temp1_input
 | 
						|
22062
 | 
						|
$
 | 
						|
$ echo 300 > update_interval
 | 
						|
$ cat update_interval
 | 
						|
375
 | 
						|
$ cat temp1_input
 | 
						|
22125
 | 
						|
$
 | 
						|
$ echo 150 > update_interval
 | 
						|
$ cat update_interval
 | 
						|
188
 | 
						|
$ cat temp1_input
 | 
						|
22250
 | 
						|
$
 | 
						|
$ echo 1 > update_interval
 | 
						|
$ cat update_interval
 | 
						|
94
 | 
						|
$ cat temp1_input
 | 
						|
22000
 | 
						|
$
 | 
						|
$ echo 1000 > update_interval
 | 
						|
$ cat update_interval
 | 
						|
750
 | 
						|
$ cat temp1_input
 | 
						|
22062
 | 
						|
$
 | 
						|
 | 
						|
As shown, the ds1621 driver automatically adjusts the 'update_interval'
 | 
						|
user input, via a step function. Reading back the 'update_interval' value
 | 
						|
after a write operation provides the conversion time used by the device.
 | 
						|
 | 
						|
Mathematically, the resolution can be derived from the conversion time
 | 
						|
via the following function:
 | 
						|
 | 
						|
   g(x) = 0.5 * [minimum_conversion_time/x]
 | 
						|
 | 
						|
where:
 | 
						|
 -> 'x' = the output from 'update_interval'
 | 
						|
 -> 'g(x)' = the resolution in degrees C per LSB.
 | 
						|
 -> 93.75ms = minimum conversion time
 |