What:		/sys/class/scsi_host/hostX/isci_id
 | 
						|
Date:		June 2011
 | 
						|
Contact:	Dave Jiang <dave.jiang@intel.com>
 | 
						|
Description:
 | 
						|
		This file contains the enumerated host ID for the Intel
 | 
						|
		SCU controller. The Intel(R) C600 Series Chipset SATA/SAS
 | 
						|
		Storage Control Unit embeds up to two 4-port controllers in
 | 
						|
		a single PCI device.  The controllers are enumerated in order
 | 
						|
		which usually means the lowest number scsi_host corresponds
 | 
						|
		with the first controller, but this association is not
 | 
						|
		guaranteed.  The 'isci_id' attribute unambiguously identifies
 | 
						|
		the controller index: '0' for the first controller,
 | 
						|
		'1' for the second.
 | 
						|
 | 
						|
What:		/sys/class/scsi_host/hostX/acciopath_status
 | 
						|
Date:		November 2013
 | 
						|
Contact:	Stephen M. Cameron <scameron@beardog.cce.hp.com>
 | 
						|
Description:	This file contains the current status of the "SSD Smart Path"
 | 
						|
		feature of HP Smart Array RAID controllers using the hpsa
 | 
						|
		driver.  SSD Smart Path, when enabled permits the driver to
 | 
						|
		send i/o requests directly to physical devices that are part
 | 
						|
		of a logical drive, bypassing the controllers firmware RAID
 | 
						|
		stack for a performance advantage when possible.  A value of
 | 
						|
		'1' indicates the feature is enabled, and the controller may
 | 
						|
		use the direct i/o path to physical devices.  A value of zero
 | 
						|
		means the feature is disabled and the controller may not use
 | 
						|
		the direct i/o path to physical devices.  This setting is
 | 
						|
		controller wide, affecting all configured logical drives on the
 | 
						|
		controller.  This file is readable and writable.
 |