* Support for indirect PCI bridges.
*
* Copyright (C) 1998 Gabriel Paubert.
*
* This program is free software; you can redistribute it and/or
* modify it under the terms of the GNU General Public License
* as published by the Free Software Foundation; either version
* 2 of the License, or (at your option) any later version.
*/
#include <linux/kernel.h>
#include <linux/pci.h>
#include <linux/delay.h>
#include <linux/string.h>
#include <linux/init.h>
#include <asm/io.h>
#include <asm/prom.h>
#include <asm/pci-bridge.h>
#include <asm/machdep.h>
static int
indirect_read_config(struct pci_bus *bus, unsigned int devfn, int offset,
int len, u32 *val)
{
struct pci_controller *hose = pci_bus_to_host(bus);
volatile void __iomem *cfg_data;
u8 cfg_type = 0;
u32 bus_no, reg;
if (hose->indirect_type & PPC_INDIRECT_TYPE_NO_PCIE_LINK) {
if (bus->number != hose->first_busno)
return PCIBIOS_DEVICE_NOT_FOUND;
if (devfn != 0)
return PCIBIOS_DEVICE_NOT_FOUND;
}
if (ppc_md.pci_exclude_device)
if (ppc_md.pci_exclude_device(hose, bus->number, devfn))
return PCIBIOS_DEVICE_NOT_FOUND;
if (hose->indirect_type & PPC_INDIRECT_TYPE_SET_CFG_TYPE)
if (bus->number != hose->first_busno)
cfg_type = 1;
bus_no = (bus->number == hose->first_busno) ?
hose->self_busno : bus->number;
if (hose->indirect_type & PPC_INDIRECT_TYPE_EXT_REG)
reg = ((offset & 0xf00) << 16) | (offset & 0xfc);
else
reg = offset & 0xfc;
if (hose->indirect_type & PPC_INDIRECT_TYPE_BIG_ENDIAN)
out_be32(hose->cfg_addr, (0x80000000 | (bus_no << 16) |
(devfn << 8) | reg | cfg_type));
else
out_le32(hose->cfg_addr, (0x80000000 | (bus_no << 16) |
(devfn << 8) | reg | cfg_type));
/*
* Note: the caller has already checked that offset is
* suitably aligned and that len is 1, 2 or 4.
*/
cfg_data = hose->cfg_data + (offset & 3);
switch (len) {
case 1:
*val = in_8(cfg_data);
break;
case 2:
*val = in_le16(cfg_data);
break;
default:
*val = in_le32(cfg_data);
break;
}
return PCIBIOS_SUCCESSFUL;
}
static int
indirect_write_config(struct pci_bus *bus, unsigned int devfn, int offset,
int len, u32 val)
{
struct pci_controller *hose = pci_bus_to_host(bus);
volatile void __iomem *cfg_data;
u8 cfg_type = 0;
u32 bus_no, reg;
if (hose->indirect_type & PPC_INDIRECT_TYPE_NO_PCIE_LINK) {
if (bus->number != hose->first_busno)
return PCIBIOS_DEVICE_NOT_FOUND;
if (devfn != 0)
return PCIBIOS_DEVICE_NOT_FOUND;
}
if (ppc_md.pci_exclude_device)
if (ppc_md.pci_exclude_device(hose, bus->number, devfn))
return PCIBIOS_DEVICE_NOT_FOUND;
if (hose->indirect_type & PPC_INDIRECT_TYPE_SET_CFG_TYPE)
if (bus->number != hose->first_busno)
cfg_type = 1;
bus_no = (bus->number == hose->first_busno) ?
hose->self_busno : bus->number;
if (hose->indirect_type & PPC_INDIRECT_TYPE_EXT_REG)
reg = ((offset & 0xf00) << 16) | (offset & 0xfc);
else
reg = offset & 0xfc;
if (hose->indirect_type & PPC_INDIRECT_TYPE_BIG_ENDIAN)
out_be32(hose->cfg_addr, (0x80000000 | (bus_no << 16) |
(devfn << 8) | reg | cfg_type));
else
out_le32(hose->cfg_addr, (0x80000000 | (bus_no << 16) |
(devfn << 8) | reg | cfg_type));
/* suppress setting of PCI_PRIMARY_BUS */
if (hose->indirect_type & PPC_INDIRECT_TYPE_SURPRESS_PRIMARY_BUS)
if ((offset == PCI_PRIMARY_BUS) &&
(bus->number == hose->first_busno))
val &= 0xffffff00;
/* Workaround for PCI_28 Errata in 440EPx/GRx */
if ((hose->indirect_type & PPC_INDIRECT_TYPE_BROKEN_MRM) &&
offset == PCI_CACHE_LINE_SIZE) {
val = 0;
}
/*
* Note: the caller has already checked that offset is
* suitably aligned and that len is 1, 2 or 4.
*/
cfg_data = hose->cfg_data + (offset & 3);
switch (len) {
case 1:
out_8(cfg_data, val);
break;
case 2:
out_le16(cfg_data, val);
break;
default:
out_le32(cfg_data, val);
break;
}
return PCIBIOS_SUCCESSFUL;
}
static struct pci_ops indirect_pci_ops =
{
.read = indirect_read_config,
.write = indirect_write_config,
};
void __init
setup_indirect_pci(struct pci_controller* hose,
resource_size_t cfg_addr,
resource_size_t cfg_data, u32 flags)
{
resource_size_t base = cfg_addr & PAGE_MASK;
void __iomem *mbase;
mbase = ioremap(base, PAGE_SIZE);
hose->cfg_addr = mbase + (cfg_addr & ~PAGE_MASK);
if ((cfg_data & PAGE_MASK) != base)
mbase = ioremap(cfg_data & PAGE_MASK, PAGE_SIZE);
hose->cfg_data = mbase + (cfg_data & ~PAGE_MASK);
hose->ops = &indirect_pci_ops;
hose->indirect_type = flags;
}