Qualcomm Technologies, Inc. CPR3 Regulator - Platform Independent Bindings
|
|
|
|
Core Power Reduction (CPR) version 3 controllers are used by some Qualcomm
|
|
Technologies, Inc. (QTI) SoCs to manage important voltage regulators. CPR3
|
|
controllers are capable of monitoring several ring oscillator sensing loops
|
|
simultaneously. The CPR3 controller informs software when the silicon
|
|
conditions require the supply voltage to be increased or decreased. On certain
|
|
supply rails, the CPR3 controller is able to propagate the voltage increase
|
|
or decrease requests all the way to the PMIC without software involvement.
|
|
|
|
This document describes the common platform independent bindings that apply
|
|
to all CPR3 controllers.
|
|
|
|
=======================
|
|
Required Node Structure
|
|
=======================
|
|
|
|
CPR3 regulators must be described in three levels of devices nodes. The first
|
|
level describes the CPR3 controller. The second level describes one or more
|
|
hardware threads managed by the controller. The third level describes one or
|
|
more logical regulators handled by each CPR thread.
|
|
|
|
====================================
|
|
First Level Nodes - CPR3 Controllers
|
|
====================================
|
|
|
|
Platform independent properties:
|
|
- compatible
|
|
Usage: required
|
|
Value type: <string>
|
|
Definition: The value to use for this property is defined in the
|
|
platform specific cpr3-regulator binding documentation
|
|
files.
|
|
|
|
- reg
|
|
Usage: required
|
|
Value type: <prop-encoded-array>
|
|
Definition: Addresses and sizes for the memory of the CPR3 controller
|
|
and the first fuse row
|
|
|
|
- reg-names
|
|
Usage: required
|
|
Value type: <stringlist>
|
|
Definition: Address names. Must be "cpr_ctrl" and "fuse_base". Must be
|
|
specified in the same order as the corresponding addresses
|
|
are specified in the reg property.
|
|
|
|
- qcom,cpr-ctrl-name
|
|
Usage: required
|
|
Value type: <string>
|
|
Definition: Name for this CPR controller
|
|
|
|
- vdd-supply
|
|
Usage: required
|
|
Value type: <phandle>
|
|
Definition: phandle of the underlying regulator device that is managed
|
|
by this CPR controller.
|
|
|
|
- system-supply
|
|
Usage: optional
|
|
Value type: <phandle>
|
|
Definition: phandle of the system-level regulator device which the
|
|
vdd-supply depends upon. Requests for this regulator must
|
|
be made before increasing the vdd-supply voltage and after
|
|
decreasing the vdd-supply voltage.
|
|
|
|
- mem-acc-supply
|
|
Usage: optional
|
|
Value type: <phandle>
|
|
Definition: phandle of the mem-acc regulator device which is used to
|
|
configure memory array circuitry settings based upon
|
|
the performance operating point. Requests for this regulator
|
|
must be made before decreasing the vdd-supply voltage and
|
|
after increasing the vdd-supply voltage.
|
|
|
|
- clocks
|
|
Usage: optional
|
|
Value type: <prop-encoded-array>
|
|
Definition: Array of clock tuples in which each tuple consists of a
|
|
phandle to a clock device and a clock ID number. The CPR3
|
|
core clock must be specified for some targets. See platform
|
|
specific cpr3-regulator binding documentation for additional
|
|
clocks that may also need to be specified.
|
|
|
|
- clock-names
|
|
Usage: optional
|
|
Value type: <stringlist>
|
|
Definition: Clock names. This list must match up 1-to-1 with the clocks
|
|
specified in the 'clocks' property. "core_clk" must be
|
|
specified for some platforms. Other clocks may be required
|
|
for some platforms.
|
|
|
|
- interrupts
|
|
Usage: required
|
|
Value type: <prop-encoded-array>
|
|
Definition: CPR interrupt specifier and optionally a hardware
|
|
closed-loop ceiling interrupt specifier.
|
|
|
|
- interrupt-names
|
|
Usage: required
|
|
Value type: <stringlist>
|
|
Definition: Interrupt names. This list must match up 1-to-1 with the
|
|
interrupts specified in the 'interrupts' property. "cpr"
|
|
must be specified. "ceiling" may be specified for some
|
|
platforms.
|
|
|
|
- qcom,cpr-sensor-time
|
|
Usage: required
|
|
Value type: <u32>
|
|
Definition: The time in nanoseconds that each CPR sensor within the
|
|
sensing loop takes to perform a measurement.
|
|
|
|
- qcom,cpr-loop-time
|
|
Usage: required
|
|
Value type: <u32>
|
|
Definition: The time in nanoseconds between consecutive CPR
|
|
measurements.
|
|
|
|
- qcom,cpr-idle-cycles
|
|
Usage: required
|
|
Value type: <u32>
|
|
Definition: The number of CPR core clock cycles for the CPR controller
|
|
to wait in transitional states.
|
|
Supported values: 0 - 31.
|
|
|
|
- qcom,voltage-step
|
|
Usage: required
|
|
Value type: <u32>
|
|
Definition: The voltage in microvolts of a single step of the VDD supply
|
|
regulator being controlled by CPR.
|
|
|
|
- qcom,cpr-step-quot-init-min
|
|
Usage: required
|
|
Value type: <u32>
|
|
Definition: The default minimum CPR step quotient value. The step
|
|
quotient is the number of additional ring oscillator ticks
|
|
observed for each qcom,voltage-step increase in vdd-supply
|
|
output voltage. Supported values: 0 - 63.
|
|
|
|
- qcom,cpr-step-quot-init-max
|
|
Usage: required
|
|
Value type: <u32>
|
|
Definition: The default maximum CPR step quotient value.
|
|
Supported values: 0 - 63.
|
|
|
|
- qcom,cpr-count-mode
|
|
Usage: required
|
|
Value type: <u32>
|
|
Definition: The CPR counting mode to use during CPR measurements.
|
|
Supported values:
|
|
0 - Read all sensors at once and use the minimum
|
|
quotient value observed in repeated measurements.
|
|
1 - Read all sensors at once and use the maximum
|
|
quotient value observed in repeated measurements.
|
|
2 - Read each sensor once in a sequential, staggered
|
|
fashion.
|
|
|
|
- qcom,cpr-count-repeat
|
|
Usage: optional
|
|
Value type: <u32>
|
|
Definition: The number of times to read CPR sensors during a single CPR
|
|
measurement when using one of the all-at-once count modes.
|
|
|
|
- qcom,cpr-enable
|
|
Usage: optional
|
|
Value type: <empty>
|
|
Definition: Boolean flag which indicates that the CPR3 controller
|
|
should operate in closed-loop mode (i.e. CPR sensing loop
|
|
enabled) as opposed to open-loop mode (i.e. CPR sensing loop
|
|
disabled) by default.
|
|
|
|
- qcom,cpr-aging-ref-voltage
|
|
Usage: required if qcom,allow-aging-voltage-adjustment is specified
|
|
for any third level nodes
|
|
Value type: <u32>
|
|
Definition: Specifies the CPR aging reference voltage in microvolts.
|
|
This is the voltage that vdd-supply must be set to when
|
|
performing an aging measurement.
|
|
|
|
=================================================
|
|
Second Level Nodes - CPR Threads for a Controller
|
|
=================================================
|
|
|
|
Platform independent properties:
|
|
- qcom,cpr-thread-id
|
|
Usage: required
|
|
Value type: <u32>
|
|
Definition: Specifies the hardware thread ID of this thread within the
|
|
CPR controller.
|
|
|
|
- qcom,cpr-consecutive-up
|
|
Usage: required
|
|
Value type: <u32>
|
|
Definition: The number of consecutive CPR step up events needed to
|
|
to trigger an up interrupt. Supported values: 0 - 15.
|
|
|
|
- qcom,cpr-consecutive-down
|
|
Usage: required
|
|
Value type: <u32>
|
|
Definition: The number of consecutive CPR step down events needed to
|
|
to trigger a down interrupt. Supported values: 0 - 15.
|
|
|
|
- qcom,cpr-up-threshold
|
|
Usage: required
|
|
Value type: <u32>
|
|
Definition: The number CPR error steps required to generate an up event.
|
|
Supported values: 0 - 31.
|
|
|
|
- qcom,cpr-down-threshold
|
|
Usage: required
|
|
Value type: <u32>
|
|
Definition: The number CPR error steps required to generate a down
|
|
event. Supported values: 0 - 31.
|
|
|
|
===============================================
|
|
Third Level Nodes - CPR Regulators for a Thread
|
|
===============================================
|
|
|
|
Platform independent properties:
|
|
- regulator-name
|
|
Usage: required
|
|
Value type: <string>
|
|
Definition: Specifies the name for this CPR3 regulator.
|
|
|
|
- regulator-min-microvolt
|
|
Usage: required
|
|
Value type: <u32>
|
|
Definition: Minimum corner value which should be 1 to represent the
|
|
lowest supported corner.
|
|
|
|
- regulator-max-microvolt
|
|
Usage: required
|
|
Value type: <u32>
|
|
Definition: Maximum corner value which should be equal to largest value
|
|
listed in qcom,cpr-corners.
|
|
|
|
- qcom,cpr-fuse-corners
|
|
Usage: required
|
|
Value type: <u32>
|
|
Definition: Specifies the number of fuse corners. See platform specific
|
|
binding files for further requirements.
|
|
|
|
- qcom,cpr-fuse-combos
|
|
Usage: required
|
|
Value type: <u32>
|
|
Definition: Specifies the number of fuse combinations being supported by
|
|
the device. This value is utilized by several other
|
|
properties. Supported values are 1 up to the maximum
|
|
possible for a given regulator type. See platform specific
|
|
binding files for further details.
|
|
|
|
- qcom,cpr-speed-bins
|
|
Usage: optional
|
|
Value type: <u32>
|
|
Definition: Specifies the number of speed bins being supported by the
|
|
device. This value is utilized by several other properties.
|
|
Supported values are 1 up to the maximum possible for a
|
|
given regulator type. See platform specific binding files
|
|
for further details.
|
|
|
|
This property can only be utilized if the number of corners
|
|
for all fuse combinations associated with a given speed bin
|
|
is the same.
|
|
|
|
- qcom,cpr-corners
|
|
Usage: required
|
|
Value type: <prop-encoded-array>
|
|
Definition: A list of integers which defines how many voltage corners
|
|
are to be used for each fuse combination. The list must
|
|
contain either qcom,cpr-fuse-combos number of elements in
|
|
which case the corner counts are applied to fuse
|
|
combinations 1-to-1 or the list must contain exactly 1
|
|
element which is used regardless of the fuse combination
|
|
found on a given chip.
|
|
|
|
- qcom,cpr-speed-bin-corners
|
|
Usage: required if qcom,cpr-speed-bins is specified
|
|
Value type: <prop-encoded-array>
|
|
Definition: A list of integers which defines how many voltage corners
|
|
are to be used for each speed bin. The list must contain
|
|
qcom,cpr-speed-bins number of elements.
|
|
|
|
- qcom,cpr-corner-fmax-map
|
|
Usage: required
|
|
Value type: <prop-encoded-array>
|
|
Definition: A list of integer tuples which each define the highest
|
|
(i.e. maximum frequency) 1-based corner value associated
|
|
with each fuse-corner.
|
|
|
|
Each tuple must have a number of elements equal to the value
|
|
of the qcom,cpr-fuse-corners property. The elements of a
|
|
tuple are ordered from lowest to highest fuse corner.
|
|
|
|
The list must contain qcom,cpr-fuse-combos number of tuples
|
|
in which case the tuples are matched to fuse combinations
|
|
1-to-1 or qcom,cpr-speed-bins number of tuples in which case
|
|
the tuples are matched to speed bins 1-to-1 or exactly 1
|
|
tuple which is used regardless of the fuse combination and
|
|
speed bin found on a given chip.
|
|
|
|
- qcom,cpr-voltage-ceiling
|
|
Usage: required
|
|
Value type: <prop-encoded-array>
|
|
Definition: A list of integer tuples which each define the CPR ceiling
|
|
voltage in microvolts for each voltage corner in order from
|
|
lowest to highest.
|
|
|
|
The list must contain qcom,cpr-fuse-combos number of tuples
|
|
in which case the tuples are matched to fuse combinations
|
|
1-to-1 or qcom,cpr-speed-bins number of tuples in which case
|
|
the tuples are matched to speed bins 1-to-1 or exactly 1
|
|
tuple which is used regardless of the fuse combination and
|
|
speed bin found on a given chip.
|
|
|
|
Each tuple must be of the length defined in the
|
|
corresponding element of the qcom,cpr-corners property or
|
|
the qcom,cpr-speed-bins property. A single tuple may only
|
|
be specified if all of the corner counts in qcom,cpr-corners
|
|
are the same.
|
|
|
|
- qcom,cpr-voltage-floor
|
|
Usage: required
|
|
Value type: <prop-encoded-array>
|
|
Definition: A list of integer tuples which each define the CPR floor
|
|
voltage in microvolts for each voltage corner in order from
|
|
lowest to highest.
|
|
|
|
The list and tuples must meet the same size requirements as
|
|
those specified for qcom,cpr-voltage-ceiling above.
|
|
|
|
- qcom,cpr-floor-to-ceiling-max-range
|
|
Usage: optional
|
|
Value type: <prop-encoded-array>
|
|
Definition: A list of integer tuples which each define the maximum
|
|
allowed difference between the final floor voltage and the
|
|
final ceiling voltage in microvolts for each voltage corner
|
|
in order from lowest to highest. A negative value may be
|
|
specified for an element to indicate that there is no
|
|
limitation of the floor to ceiling voltage range for the
|
|
corresponding corner.
|
|
|
|
In the case that the initial floor to ceiling voltage is
|
|
greater than the max range specified, the floor voltage will
|
|
be increased in order to satisfy the max range constraint.
|
|
|
|
The list and tuples must meet the same size requirements as
|
|
those specified for qcom,cpr-voltage-ceiling above.
|
|
|
|
- qcom,system-voltage
|
|
Usage: optional
|
|
Value type: <prop-encoded-array>
|
|
Definition: A list of integer tuples which each define the system-supply
|
|
voltage in microvolts or corners or levels for each voltage
|
|
corner in order from lowest to highest.
|
|
|
|
The list and tuples must meet the same size requirements as
|
|
those specified for qcom,cpr-voltage-ceiling above.
|
|
|
|
- qcom,corner-frequencies
|
|
Usage: required
|
|
Value type: <prop-encoded-array>
|
|
Definition: A list of integer tuples which each define the CPU frequency
|
|
in Hertz corresponding to each voltage corner in order from
|
|
lowest to highest.
|
|
|
|
The list and tuples must meet the same size requirements as
|
|
those specified for qcom,cpr-voltage-ceiling above.
|
|
|
|
- qcom,allow-voltage-interpolation
|
|
Usage: optional
|
|
Value type: <empty>
|
|
Definition: Boolean flag which indicates that it is acceptable to use
|
|
interpolated open-loop voltage values. These values are
|
|
interpolated between the open-loop voltage Fmax fuse values.
|
|
|
|
- qcom,cpr-scaled-open-loop-voltage-as-ceiling
|
|
Usage: optional
|
|
Value type: <empty>
|
|
Definition: Boolean flag which indicates that it is acceptable to use
|
|
the interpolated open-loop voltage for each corner as the
|
|
CPR ceiling voltage for each corner.
|
|
|
|
- qcom,cpr-open-loop-voltage-fuse-adjustment
|
|
Usage: optional
|
|
Value type: <prop-encoded-array>
|
|
Definition: A list of integer tuples which each define the open-loop
|
|
voltage adjustment in microvolts for each fused voltage
|
|
corner in order from lowest to highest. This adjustment is
|
|
applied to the values read from fuses before the values are
|
|
used in interpolation for intermediate corners.
|
|
|
|
The list and tuples must meet the same size requirements as
|
|
those specified for qcom,cpr-corner-fmax-map above.
|
|
|
|
The open-loop voltage for a given fuse corner corresponds to
|
|
the voltage that is safe to use under all circumstances.
|
|
It is used as a starting voltage for CPR and may also be
|
|
specified as a ceiling voltage for CPR scaling.
|
|
|
|
- qcom,cpr-open-loop-voltage-adjustment
|
|
Usage: optional
|
|
Value type: <prop-encoded-array>
|
|
Definition: A list of integer tuples which each define the open-loop
|
|
voltage adjustment in microvolts for each voltage corner in
|
|
order from lowest to highest. This adjustment is applied to
|
|
the open-loop voltage values after they have been
|
|
interpolated for intermediate corners.
|
|
|
|
The list and tuples must meet the same size requirements as
|
|
those specified for qcom,cpr-voltage-ceiling above.
|
|
|
|
- qcom,cpr-open-loop-voltage-min-diff
|
|
Usage: optional; only meaningful if the
|
|
qcom,cpr-open-loop-voltage-adjustment property is specified
|
|
Value type: <prop-encoded-array>
|
|
Definition: A list of integer tuples which each define the minimum
|
|
allowed open-loop voltage difference in microvolts between
|
|
each voltage corner and the one immediately preceding it.
|
|
The elements in a tuple are ordered from the lowest to the
|
|
highest corner. The value specified for the first corner is
|
|
ignored since there is no corner before it.
|
|
|
|
Negative voltage values may be specified for this property.
|
|
A negative value means that the open-loop voltage of a
|
|
corner may be lower than that of the preceding corner.
|
|
|
|
The minimum difference is enforced after the open-loop
|
|
voltage values have been interpolated for intermediate
|
|
corners and after adjustments have been applied.
|
|
|
|
The list and tuples must meet the same size requirements as
|
|
those specified for qcom,cpr-voltage-ceiling above.
|
|
|
|
If this property is not specified, then the minimum
|
|
difference is assumed to be 0 uV for all corners.
|
|
|
|
- qcom,cpr-closed-loop-voltage-fuse-adjustment
|
|
Usage: optional
|
|
Value type: <prop-encoded-array>
|
|
Definition: A list of integer tuples which each define the closed-loop
|
|
voltage adjustment in microvolts for each fused voltage
|
|
corner in order from lowest to highest. This adjustment is
|
|
applied to the values read from fuses before the values are
|
|
used in interpolation for intermediate corners.
|
|
|
|
The list and tuples must meet the same size requirements as
|
|
those specified for qcom,cpr-corner-fmax-map above.
|
|
|
|
The qcom,cpr-ro-scaling-factor property must be specified in
|
|
order to utilize this property.
|
|
|
|
The closed-loop voltage for a given fuse corner corresponds
|
|
to the voltage that the CPR controller settles the VDD
|
|
supply rail to based upon the programmed CPR target
|
|
quotients and the current silicon conditions.
|
|
|
|
- qcom,cpr-closed-loop-voltage-adjustment
|
|
Usage: optional
|
|
Value type: <prop-encoded-array>
|
|
Definition: A list of integer tuples which each define the closed-loop
|
|
voltage adjustment in microvolts for each voltage corner in
|
|
order from lowest to highest. This adjustment is applied to
|
|
target quotient values after they have been interpolated
|
|
for intermediate corners.
|
|
|
|
The list and tuples must meet the same size requirements as
|
|
those specified for qcom,cpr-voltage-ceiling above.
|
|
|
|
The qcom,cpr-ro-scaling-factor property must be specified in
|
|
order to utilize this property.
|
|
|
|
- qcom,cpr-ro-scaling-factor
|
|
Usage: required if qcom,cpr-closed-loop-voltage-fuse-adjustment,
|
|
qcom,cpr-closed-loop-voltage-adjustment, or
|
|
qcom,allow-aging-voltage-adjustment is specified
|
|
Value type: <prop-encoded-array>
|
|
Definition: A grouping of integer tuple lists. Each tuple defines the
|
|
CPR ring oscillator (RO) scaling factor with units of QUOT/V
|
|
for each RO for a given fuse corner. Since CPR3 supports
|
|
exactly 16 ROs, each tuple must contain 16 elements
|
|
corresponding to RO0 through RO15 in order. If a given RO
|
|
is unused for a fuse corner, then its scaling factor may be
|
|
specified as 0.
|
|
|
|
Each tuple list must contain the number of tuples defined in
|
|
the qcom,cpr-fuse-corners property. The tuples in a given
|
|
list are ordered from the lowest fuse corner to the highest
|
|
fuse corner.
|
|
|
|
The tuple list grouping must contain qcom,cpr-fuse-combos
|
|
number of tuple lists in which case the lists are matched to
|
|
fuse combinations 1-to-1 or qcom,cpr-speed-bins number of
|
|
tuple lists in which case the lists are matched to
|
|
speed bins 1-to-1 or exactly 1 list which is used regardless
|
|
of the fuse combination and speed bin found on a given chip.
|
|
|
|
The target quotient adjustment to apply for each RO of a
|
|
given corner is determined by multiplying the adjustment
|
|
value in qcom,cpr-closed-loop-voltage-fuse-adjustment or
|
|
qcom,cpr-closed-loop-voltage-adjustment by the relevant RO
|
|
scaling factor in this property.
|
|
|
|
- qcom,allow-aging-voltage-adjustment
|
|
Usage: optional
|
|
Value type: <prop-encoded-array>
|
|
Definition: A list of integers which specifies if CPR aging adjustment
|
|
should be performed for each fuse combination.
|
|
Supported per-combo element values:
|
|
0 - do not perform CPR aging adjustment
|
|
1 - perform CPR aging adjustment
|
|
|
|
The list must contain qcom,cpr-fuse-combos number of
|
|
elements in which case the elements are matched to fuse
|
|
combinations 1-to-1 or qcom,cpr-speed-bins number of
|
|
elements in which case the elements are matched to
|
|
speed bins 1-to-1 or exactly 1 element which is used
|
|
regardless of the fuse combination and speed bin found
|
|
on a given chip.
|
|
|
|
- qcom,cpr-aging-max-voltage-adjustment
|
|
Usage: required if qcom,allow-aging-voltage-adjustment is specified
|
|
Value type: <prop-encoded-array>
|
|
Definition: A list of integers which defines the maximum CPR aging
|
|
voltage margin adjustment in microvolts that may be added
|
|
for each fuse combination. If this property is specified
|
|
and the adjustment specified is greater than 0, then aging
|
|
adjustments are required for this regulator.
|
|
|
|
The list must meet the same size requirements as those
|
|
specified for qcom,allow-aging-voltage-adjustment above.
|
|
|
|
- qcom,cpr-aging-ref-corner
|
|
Usage: required if qcom,allow-aging-voltage-adjustment is specified
|
|
Value type: <prop-encoded-array>
|
|
Definition: A list of integers which defines the CPR reference corner
|
|
for this regulator to use during aging measurements for each
|
|
fuse combination.
|
|
|
|
The list must meet the same size requirements as those
|
|
specified for qcom,allow-aging-voltage-adjustment above.
|
|
|
|
- qcom,cpr-aging-ro-scaling-factor
|
|
Usage: required if qcom,allow-aging-voltage-adjustment is specified
|
|
Value type: <prop-encoded-array>
|
|
Definition: A list of integers which defines the CPR aging ring
|
|
oscillator (RO) scaling factor with units of QUOT/V to use
|
|
during aging measurements for each fuse combination.
|
|
|
|
The list must meet the same size requirements as those
|
|
specified for qcom,allow-aging-voltage-adjustment above.
|
|
|
|
- qcom,cpr-aging-derate
|
|
Usage: optional, though only meaningful if
|
|
qcom,allow-aging-voltage-adjustment is specified
|
|
Value type: <prop-encoded-array>
|
|
Definition: A list of integer tuples which each define the CPR aging
|
|
derating scaling factor to apply to the closed-loop voltage
|
|
margin adjustment for each corner. The individual scaling
|
|
factors have units of uV/mV and are ordered from lowest to
|
|
highest corner per tuple. For example, a value of 900
|
|
specifies that the voltage adjustment for the corner should
|
|
be 90% (900/1000) of that for the reference corner.
|
|
|
|
The list and tuples must meet the same size requirements as
|
|
those specified for qcom,cpr-voltage-ceiling above.
|
|
|
|
If this property is not specified, then it is assumed that
|
|
no corners require derating (i.e. the scaling factor would
|
|
be 1000).
|
|
|
|
All properties specified within the core regulator framework can also be used in
|
|
third level nodes. These bindings can be found in:
|
|
Documentation/devicetree/bindings/regulator/regulator.txt.
|
|
|
|
See platform specific cpr3-regulator binding documentation files for examples.
|