* Freescale Serial RapidIO (SRIO) Controller
|
|
|
|
RapidIO port node:
|
|
Properties:
|
|
- compatible
|
|
Usage: required
|
|
Value type: <string>
|
|
Definition: Must include "fsl,srio" for IP blocks with IP Block
|
|
Revision Register (SRIO IPBRR1) Major ID equal to 0x01c0.
|
|
|
|
Optionally, a compatible string of "fsl,srio-vX.Y" where X is Major
|
|
version in IP Block Revision Register and Y is Minor version. If this
|
|
compatible is provided it should be ordered before "fsl,srio".
|
|
|
|
- reg
|
|
Usage: required
|
|
Value type: <prop-encoded-array>
|
|
Definition: A standard property. Specifies the physical address and
|
|
length of the SRIO configuration registers. The size should
|
|
be set to 0x11000.
|
|
|
|
- interrupts
|
|
Usage: required
|
|
Value type: <prop_encoded-array>
|
|
Definition: Specifies the interrupts generated by this device. The
|
|
value of the interrupts property consists of one interrupt
|
|
specifier. The format of the specifier is defined by the
|
|
binding document describing the node's interrupt parent.
|
|
|
|
A single IRQ that handles error conditions is specified by this
|
|
property. (Typically shared with port-write).
|
|
|
|
- fsl,srio-rmu-handle:
|
|
Usage: required if rmu node is defined
|
|
Value type: <phandle>
|
|
Definition: A single <phandle> value that points to the RMU.
|
|
(See srio-rmu.txt for more details on RMU node binding)
|
|
|
|
Port Child Nodes: There should a port child node for each port that exists in
|
|
the controller. The ports are numbered starting at one (1) and should have
|
|
the following properties:
|
|
|
|
- cell-index
|
|
Usage: required
|
|
Value type: <u32>
|
|
Definition: A standard property. Matches the port id.
|
|
|
|
- ranges
|
|
Usage: required if local access windows preset
|
|
Value type: <prop-encoded-array>
|
|
Definition: A standard property. Utilized to describe the memory mapped
|
|
IO space utilized by the controller. This corresponds to the
|
|
setting of the local access windows that are targeted to this
|
|
SRIO port.
|
|
|
|
- fsl,liodn
|
|
Usage: optional-but-recommended (for devices with PAMU)
|
|
Value type: <prop-encoded-array>
|
|
Definition: The logical I/O device number for the PAMU (IOMMU) to be
|
|
correctly configured for SRIO accesses. The property should
|
|
not exist on devices that do not support PAMU.
|
|
|
|
For HW (ie, the P4080) that only supports a LIODN for both
|
|
memory and maintenance transactions then a single LIODN is
|
|
represented in the property for both transactions.
|
|
|
|
For HW (ie, the P304x/P5020, etc) that supports an LIODN for
|
|
memory transactions and a unique LIODN for maintenance
|
|
transactions then a pair of LIODNs are represented in the
|
|
property. Within the pair, the first element represents the
|
|
LIODN associated with memory transactions and the second element
|
|
represents the LIODN associated with maintenance transactions
|
|
for the port.
|
|
|
|
Note: All other standard properties (see ePAPR) are allowed but are optional.
|
|
|
|
Example:
|
|
|
|
rapidio: rapidio@ffe0c0000 {
|
|
#address-cells = <2>;
|
|
#size-cells = <2>;
|
|
reg = <0xf 0xfe0c0000 0 0x11000>;
|
|
compatible = "fsl,srio";
|
|
interrupts = <16 2 1 11>; /* err_irq */
|
|
fsl,srio-rmu-handle = <&rmu>;
|
|
ranges;
|
|
|
|
port1 {
|
|
cell-index = <1>;
|
|
#address-cells = <2>;
|
|
#size-cells = <2>;
|
|
fsl,liodn = <34>;
|
|
ranges = <0 0 0xc 0x20000000 0 0x10000000>;
|
|
};
|
|
|
|
port2 {
|
|
cell-index = <2>;
|
|
#address-cells = <2>;
|
|
#size-cells = <2>;
|
|
fsl,liodn = <48>;
|
|
ranges = <0 0 0xc 0x30000000 0 0x10000000>;
|
|
};
|
|
};
|