75 lines
		
	
	
		
			2.2 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
			
		
		
	
	
			75 lines
		
	
	
		
			2.2 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
| Kernel driver sht15
 | |
| ===================
 | |
| 
 | |
| Authors:
 | |
|   * Wouter Horre
 | |
|   * Jonathan Cameron
 | |
|   * Vivien Didelot <vivien.didelot@savoirfairelinux.com>
 | |
|   * Jerome Oufella <jerome.oufella@savoirfairelinux.com>
 | |
| 
 | |
| Supported chips:
 | |
|   * Sensirion SHT10
 | |
|     Prefix: 'sht10'
 | |
| 
 | |
|   * Sensirion SHT11
 | |
|     Prefix: 'sht11'
 | |
| 
 | |
|   * Sensirion SHT15
 | |
|     Prefix: 'sht15'
 | |
| 
 | |
|   * Sensirion SHT71
 | |
|     Prefix: 'sht71'
 | |
| 
 | |
|   * Sensirion SHT75
 | |
|     Prefix: 'sht75'
 | |
| 
 | |
| Datasheet: Publicly available at the Sensirion website
 | |
| http://www.sensirion.ch/en/pdf/product_information/Datasheet-humidity-sensor-SHT1x.pdf
 | |
| 
 | |
| Description
 | |
| -----------
 | |
| 
 | |
| The SHT10, SHT11, SHT15, SHT71, and SHT75 are humidity and temperature
 | |
| sensors.
 | |
| 
 | |
| The devices communicate using two GPIO lines.
 | |
| 
 | |
| Supported resolutions for the measurements are 14 bits for temperature and 12
 | |
| bits for humidity, or 12 bits for temperature and 8 bits for humidity.
 | |
| 
 | |
| The humidity calibration coefficients are programmed into an OTP memory on the
 | |
| chip. These coefficients are used to internally calibrate the signals from the
 | |
| sensors. Disabling the reload of those coefficients allows saving 10ms for each
 | |
| measurement and decrease power consumption, while losing on precision.
 | |
| 
 | |
| Some options may be set directly in the sht15_platform_data structure
 | |
| or via sysfs attributes.
 | |
| 
 | |
| Notes:
 | |
|   * The regulator supply name is set to "vcc".
 | |
|   * If a CRC validation fails, a soft reset command is sent, which resets
 | |
|     status register to its hardware default value, but the driver will try to
 | |
|     restore the previous device configuration.
 | |
| 
 | |
| Platform data
 | |
| -------------
 | |
| 
 | |
| * checksum:
 | |
|   set it to true to enable CRC validation of the readings (default to false).
 | |
| * no_otp_reload:
 | |
|   flag to indicate not to reload from OTP (default to false).
 | |
| * low_resolution:
 | |
|   flag to indicate the temp/humidity resolution to use (default to false).
 | |
| 
 | |
| Sysfs interface
 | |
| ---------------
 | |
| 
 | |
| * temp1_input:     temperature input
 | |
| * humidity1_input: humidity input
 | |
| * heater_enable:   write 1 in this attribute to enable the on-chip heater,
 | |
|                    0 to disable it. Be careful not to enable the heater
 | |
|                    for too long.
 | |
| * temp1_fault:     if 1, this means that the voltage is low (below 2.47V) and
 | |
|                    measurement may be invalid.
 | |
| * humidity1_fault: same as temp1_fault.
 | 