Allwinner sunxi Peripheral Reset Controller
|
||
|
===========================================
|
||
|
|
||
|
Please also refer to reset.txt in this directory for common reset
|
||
|
controller binding usage.
|
||
|
|
||
|
Required properties:
|
||
|
- compatible: Should be one of the following:
|
||
|
"allwinner,sun6i-a31-ahb1-reset"
|
||
|
"allwinner,sun6i-a31-clock-reset"
|
||
|
- reg: should be register base and length as documented in the
|
||
|
datasheet
|
||
|
- #reset-cells: 1, see below
|
||
|
|
||
|
example:
|
||
|
|
||
|
ahb1_rst: reset@01c202c0 {
|
||
|
#reset-cells = <1>;
|
||
|
compatible = "allwinner,sun6i-a31-ahb1-reset";
|
||
|
reg = <0x01c202c0 0xc>;
|
||
|
};
|