SMB135x battery charger
|
||
|
|
||
|
SMB135x is a single-cell switching mode battery charger. It can charge
|
||
|
the battery and power the system via the USB and AC adapter input.
|
||
|
|
||
|
The smb135x interface is via I2C bus.
|
||
|
|
||
|
Required Properties:
|
||
|
- compatible: Must be "qcom,smb1357-charger", "qcom,smb1358-charger"
|
||
|
or "qcom,smb1359-charger".
|
||
|
- reg: The device 7-bit I2C address.
|
||
|
|
||
|
Optional Properties:
|
||
|
|
||
|
- interrupts This indicates the IRQ number of the GPIO
|
||
|
connected to the STAT pin.
|
||
|
- qcom,bms-psy-name the psy name to use for reporting battery capacity. If left
|
||
|
unspecified it uses a preprogrammed default value.
|
||
|
- qcom,float-voltage-mv Float Voltage in mV - the maximum voltage up to which
|
||
|
the battery is charged. Supported range 3600mV to 4500mV
|
||
|
- qcom,charging-timeout Maximum duration in minutes that a single charge
|
||
|
cycle may last. Supported values are: 0, 192, 384,
|
||
|
768, and 1536. A value of 0 means that no
|
||
|
charge cycle timeout is used and charging can
|
||
|
continue indefinitely.
|
||
|
- qcom,dc-psy-type The type of charger connected to the DC path.
|
||
|
Can be "Mains" or "Wireless"
|
||
|
- qcom,dc-psy-ma The current in mA dc path can support. Must be specified if
|
||
|
dc-psy-type is specified. Valid range 300mA to 2000mA.
|
||
|
- qcom,charging-disabled Set this if charging should be disabled in the build
|
||
|
by default. Useful in usecases where battery current
|
||
|
needs to be profiled even when USB is present.
|
||
|
- qcom,recharge-thresh-mv Specifies the minimum voltage drop in millivolts
|
||
|
below the float voltage that is required in
|
||
|
order to initiate a new charging cycle.
|
||
|
Supported values are: 50, 100, 200 and 300mV.
|
||
|
- qcom,bmd-algo-disabled Indicates if the battery missing detection algorithm
|
||
|
is disabled. If this node is present SMB uses
|
||
|
the THERM pin for battery missing detection.
|
||
|
- qcom,iterm-ma Specifies the termination current to indicate end-of-charge.
|
||
|
Possible values in mA - 50, 100, 150, 200, 250, 300, 500, 600.
|
||
|
- qcom,iterm-disabled Disables the termination current feature. This is a bool
|
||
|
property.
|
||
|
- qcom,soft-vfloat-comp-disabled Set this property when the battery is powered via external
|
||
|
source and could go above the float voltage. smb135x chips
|
||
|
go in to unintentional reverse boost in such a situation and
|
||
|
the float voltage compensation needs to be disabled to avoid
|
||
|
that reverse boost.
|
||
|
- qcom,soft-current-comp-disabled Set this property to disable charging current compensation
|
||
|
if battery temperature exceeds soft JEITA thresholds.
|
||
|
- qcom,gamma-setting Array of gamma values for JEITA. The sequence is
|
||
|
<"Cold Hard" "Hot Hard" "Cold Soft" "Hot Soft">. Gamma value
|
||
|
indicates the ratio of the pull up resistors and NTC
|
||
|
resistor in battery pack. There are 4 options refering to
|
||
|
the graphic user interface.
|
||
|
- qcom,thermal-mitigation: Array of input current limit values for different
|
||
|
system thermal mitigation level.
|
||
|
- regulator-name A string used as a descriptive name for OTG regulator.
|
||
|
- therm-bias-supply The supply that provides bias voltage to the battery
|
||
|
thermistor. This is useful in designs that do not use the SYSON
|
||
|
pin to bias the thermistor.
|
||
|
- usb-pullup-supply The supply regulator that act as pull-up for USB data lines.
|
||
|
- qcom,parallel-charger: A flag to indicate if the charger merely assists for USB
|
||
|
charging. In this case the input current from USB is split
|
||
|
between a main charger and smb135x for reducing thermal impact
|
||
|
of high current charging from USB path.
|
||
|
- qcom,inhibit-disabled: Disables the charger-inhibit function.
|
||
|
- qcom,bms-controlled-charging: This property enables BMS to control EOC and
|
||
|
recharge. BMS and charger communicates with each
|
||
|
other via power_supply framework. This
|
||
|
property should be used with 'qcom,iterm-disabled'
|
||
|
to ensure EOC detection in charger is
|
||
|
disabled.
|
||
|
- qcom,fastchg-ma: Specifies the maximum fastcharge current.
|
||
|
The possible range for fastcharge current is
|
||
|
from 300mA to 3000mA.
|
||
|
- qcom,id-line-not-connected: Specifies if smb135x charger is not monitoring the USB_ID line.
|
||
|
|
||
|
Example:
|
||
|
i2c@f9967000 {
|
||
|
smb1357-charger@1b {
|
||
|
compatible = "qcom,smb1357-charger";
|
||
|
reg = <0x1b>;
|
||
|
interrupt-parent = <&spmi_bus>;
|
||
|
interrupts = <0x00 0xCD 0>;
|
||
|
qcom,float-voltage-mv = <4200>;
|
||
|
qcom,iterm-ma = <100>;
|
||
|
qcom,dc-psy-type = <8>;
|
||
|
qcom,dc-psy-ma = <800>;
|
||
|
qcom,charging-disabled;
|
||
|
qcom,recharge-thresh-mv = <100>;
|
||
|
regulator-name = "smb1357-otg";
|
||
|
qcom,thermal-mitigation = <1500 700 600 325>;
|
||
|
qcom,gamma-setting = <3 2 0 2>;
|
||
|
qcom,fastchg-ma = <3000>;
|
||
|
};
|
||
|
};
|