M7350/kernel/arch/powerpc/kvm/Kconfig

183 lines
5.0 KiB
Plaintext
Raw Normal View History

2024-09-09 08:52:07 +00:00
#
# KVM configuration
#
source "virt/kvm/Kconfig"
menuconfig VIRTUALIZATION
bool "Virtualization"
---help---
Say Y here to get to see options for using your Linux host to run
other operating systems inside virtual machines (guests).
This option alone does not add any kernel code.
If you say N, all options in this submenu will be skipped and
disabled.
if VIRTUALIZATION
config KVM
bool
select PREEMPT_NOTIFIERS
select ANON_INODES
2024-09-09 08:57:42 +00:00
select HAVE_KVM_EVENTFD
2024-09-09 08:52:07 +00:00
config KVM_BOOK3S_HANDLER
bool
config KVM_BOOK3S_32_HANDLER
bool
select KVM_BOOK3S_HANDLER
select KVM_MMIO
config KVM_BOOK3S_64_HANDLER
bool
select KVM_BOOK3S_HANDLER
2024-09-09 08:57:42 +00:00
config KVM_BOOK3S_PR_POSSIBLE
2024-09-09 08:52:07 +00:00
bool
select KVM_MMIO
2024-09-09 08:57:42 +00:00
select MMU_NOTIFIER
config KVM_BOOK3S_HV_POSSIBLE
bool
2024-09-09 08:52:07 +00:00
config KVM_BOOK3S_32
tristate "KVM support for PowerPC book3s_32 processors"
2024-09-09 08:57:42 +00:00
depends on PPC_BOOK3S_32 && !SMP && !PTE_64BIT
2024-09-09 08:52:07 +00:00
select KVM
select KVM_BOOK3S_32_HANDLER
2024-09-09 08:57:42 +00:00
select KVM_BOOK3S_PR_POSSIBLE
2024-09-09 08:52:07 +00:00
---help---
Support running unmodified book3s_32 guest kernels
in virtual machines on book3s_32 host processors.
This module provides access to the hardware capabilities through
a character device node named /dev/kvm.
If unsure, say N.
config KVM_BOOK3S_64
tristate "KVM support for PowerPC book3s_64 processors"
2024-09-09 08:57:42 +00:00
depends on PPC_BOOK3S_64
2024-09-09 08:52:07 +00:00
select KVM_BOOK3S_64_HANDLER
select KVM
2024-09-09 08:57:42 +00:00
select KVM_BOOK3S_PR_POSSIBLE if !KVM_BOOK3S_HV_POSSIBLE
2024-09-09 08:52:07 +00:00
---help---
Support running unmodified book3s_64 and book3s_32 guest kernels
in virtual machines on book3s_64 host processors.
This module provides access to the hardware capabilities through
a character device node named /dev/kvm.
If unsure, say N.
config KVM_BOOK3S_64_HV
2024-09-09 08:57:42 +00:00
tristate "KVM support for POWER7 and PPC970 using hypervisor mode in host"
2024-09-09 08:52:07 +00:00
depends on KVM_BOOK3S_64
2024-09-09 08:57:42 +00:00
select KVM_BOOK3S_HV_POSSIBLE
2024-09-09 08:52:07 +00:00
select MMU_NOTIFIER
2024-09-09 08:57:42 +00:00
select CMA
2024-09-09 08:52:07 +00:00
---help---
Support running unmodified book3s_64 guest kernels in
virtual machines on POWER7 and PPC970 processors that have
hypervisor mode available to the host.
If you say Y here, KVM will use the hardware virtualization
facilities of POWER7 (and later) processors, meaning that
guest operating systems will run at full hardware speed
using supervisor and user modes. However, this also means
that KVM is not usable under PowerVM (pHyp), is only usable
on POWER7 (or later) processors and PPC970-family processors,
and cannot emulate a different processor from the host processor.
If unsure, say N.
config KVM_BOOK3S_64_PR
2024-09-09 08:57:42 +00:00
tristate "KVM support without using hypervisor mode in host"
depends on KVM_BOOK3S_64
select KVM_BOOK3S_PR_POSSIBLE
2024-09-09 08:52:07 +00:00
---help---
2024-09-09 08:57:42 +00:00
Support running guest kernels in virtual machines on processors
without using hypervisor mode in the host, by running the
guest in user mode (problem state) and emulating all
privileged instructions and registers.
This is not as fast as using hypervisor mode, but works on
machines where hypervisor mode is not available or not usable,
and can emulate processors that are different from the host
processor, including emulating 32-bit processors on a 64-bit
host.
config KVM_BOOKE_HV
bool
2024-09-09 08:52:07 +00:00
config KVM_EXIT_TIMING
bool "Detailed exit timing"
2024-09-09 08:57:42 +00:00
depends on KVM_E500V2 || KVM_E500MC
2024-09-09 08:52:07 +00:00
---help---
Calculate elapsed time for every exit/enter cycle. A per-vcpu
report is available in debugfs kvm/vm#_vcpu#_timing.
The overhead is relatively small, however it is not recommended for
production environments.
If unsure, say N.
2024-09-09 08:57:42 +00:00
config KVM_E500V2
bool "KVM support for PowerPC E500v2 processors"
depends on E500 && !PPC_E500MC
2024-09-09 08:52:07 +00:00
select KVM
select KVM_MMIO
2024-09-09 08:57:42 +00:00
select MMU_NOTIFIER
2024-09-09 08:52:07 +00:00
---help---
Support running unmodified E500 guest kernels in virtual machines on
2024-09-09 08:57:42 +00:00
E500v2 host processors.
2024-09-09 08:52:07 +00:00
This module provides access to the hardware capabilities through
a character device node named /dev/kvm.
If unsure, say N.
2024-09-09 08:57:42 +00:00
config KVM_E500MC
bool "KVM support for PowerPC E500MC/E5500/E6500 processors"
depends on PPC_E500MC
select KVM
select KVM_MMIO
select KVM_BOOKE_HV
select MMU_NOTIFIER
---help---
Support running unmodified E500MC/E5500/E6500 guest kernels in
virtual machines on E500MC/E5500/E6500 host processors.
This module provides access to the hardware capabilities through
a character device node named /dev/kvm.
If unsure, say N.
config KVM_MPIC
bool "KVM in-kernel MPIC emulation"
depends on KVM && E500
select HAVE_KVM_IRQCHIP
select HAVE_KVM_IRQFD
select HAVE_KVM_IRQ_ROUTING
select HAVE_KVM_MSI
help
Enable support for emulating MPIC devices inside the
host kernel, rather than relying on userspace to emulate.
Currently, support is limited to certain versions of
Freescale's MPIC implementation.
config KVM_XICS
bool "KVM in-kernel XICS emulation"
depends on KVM_BOOK3S_64 && !KVM_MPIC
select HAVE_KVM_IRQCHIP
select HAVE_KVM_IRQFD
---help---
Include support for the XICS (eXternal Interrupt Controller
Specification) interrupt controller architecture used on
IBM POWER (pSeries) servers.
2024-09-09 08:52:07 +00:00
source drivers/vhost/Kconfig
endif # VIRTUALIZATION