Ralink Watchdog Timers
Required properties:
- compatible: must be "ralink,rt2880-wdt"
- reg: physical base address of the controller and length of the register range
Optional properties:
- interrupt-parent: phandle to the INTC device node
- interrupts: Specify the INTC interrupt number
Example:
watchdog@120 {
compatible = "ralink,rt2880-wdt";
reg = <0x120 0x10>;
interrupt-parent = <&intc>;
interrupts = <1>;
};