111 lines
4.4 KiB
Plaintext
111 lines
4.4 KiB
Plaintext
|
Kernel driver ucd9000
|
||
|
=====================
|
||
|
|
||
|
Supported chips:
|
||
|
* TI UCD90120, UCD90124, UCD9090, and UCD90910
|
||
|
Prefixes: 'ucd90120', 'ucd90124', 'ucd9090', 'ucd90910'
|
||
|
Addresses scanned: -
|
||
|
Datasheets:
|
||
|
http://focus.ti.com/lit/ds/symlink/ucd90120.pdf
|
||
|
http://focus.ti.com/lit/ds/symlink/ucd90124.pdf
|
||
|
http://focus.ti.com/lit/ds/symlink/ucd9090.pdf
|
||
|
http://focus.ti.com/lit/ds/symlink/ucd90910.pdf
|
||
|
|
||
|
Author: Guenter Roeck <guenter.roeck@ericsson.com>
|
||
|
|
||
|
|
||
|
Description
|
||
|
-----------
|
||
|
|
||
|
From datasheets:
|
||
|
|
||
|
The UCD90120 Power Supply Sequencer and System Health Monitor monitors and
|
||
|
sequences up to 12 independent voltage rails. The device integrates a 12-bit
|
||
|
ADC with a 2.5V internal reference for monitoring up to 13 power supply voltage,
|
||
|
current, or temperature inputs.
|
||
|
|
||
|
The UCD90124 is a 12-rail PMBus/I2C addressable power-supply sequencer and
|
||
|
system-health monitor. The device integrates a 12-bit ADC for monitoring up to
|
||
|
13 power-supply voltage, current, or temperature inputs. Twenty-six GPIO pins
|
||
|
can be used for power supply enables, power-on reset signals, external
|
||
|
interrupts, cascading, or other system functions. Twelve of these pins offer PWM
|
||
|
functionality. Using these pins, the UCD90124 offers support for fan control,
|
||
|
margining, and general-purpose PWM functions.
|
||
|
|
||
|
The UCD9090 is a 10-rail PMBus/I2C addressable power-supply sequencer and
|
||
|
monitor. The device integrates a 12-bit ADC for monitoring up to 10 power-supply
|
||
|
voltage inputs. Twenty-three GPIO pins can be used for power supply enables,
|
||
|
power-on reset signals, external interrupts, cascading, or other system
|
||
|
functions. Ten of these pins offer PWM functionality. Using these pins, the
|
||
|
UCD9090 offers support for margining, and general-purpose PWM functions.
|
||
|
|
||
|
The UCD90910 is a ten-rail I2C / PMBus addressable power-supply sequencer and
|
||
|
system-health monitor. The device integrates a 12-bit ADC for monitoring up to
|
||
|
13 power-supply voltage, current, or temperature inputs.
|
||
|
|
||
|
This driver is a client driver to the core PMBus driver. Please see
|
||
|
Documentation/hwmon/pmbus for details on PMBus client drivers.
|
||
|
|
||
|
|
||
|
Usage Notes
|
||
|
-----------
|
||
|
|
||
|
This driver does not auto-detect devices. You will have to instantiate the
|
||
|
devices explicitly. Please see Documentation/i2c/instantiating-devices for
|
||
|
details.
|
||
|
|
||
|
|
||
|
Platform data support
|
||
|
---------------------
|
||
|
|
||
|
The driver supports standard PMBus driver platform data. Please see
|
||
|
Documentation/hwmon/pmbus for details.
|
||
|
|
||
|
|
||
|
Sysfs entries
|
||
|
-------------
|
||
|
|
||
|
The following attributes are supported. Limits are read-write; all other
|
||
|
attributes are read-only.
|
||
|
|
||
|
in[1-12]_label "vout[1-12]".
|
||
|
in[1-12]_input Measured voltage. From READ_VOUT register.
|
||
|
in[1-12]_min Minimum Voltage. From VOUT_UV_WARN_LIMIT register.
|
||
|
in[1-12]_max Maximum voltage. From VOUT_OV_WARN_LIMIT register.
|
||
|
in[1-12]_lcrit Critical minimum Voltage. VOUT_UV_FAULT_LIMIT register.
|
||
|
in[1-12]_crit Critical maximum voltage. From VOUT_OV_FAULT_LIMIT register.
|
||
|
in[1-12]_min_alarm Voltage low alarm. From VOLTAGE_UV_WARNING status.
|
||
|
in[1-12]_max_alarm Voltage high alarm. From VOLTAGE_OV_WARNING status.
|
||
|
in[1-12]_lcrit_alarm Voltage critical low alarm. From VOLTAGE_UV_FAULT status.
|
||
|
in[1-12]_crit_alarm Voltage critical high alarm. From VOLTAGE_OV_FAULT status.
|
||
|
|
||
|
curr[1-12]_label "iout[1-12]".
|
||
|
curr[1-12]_input Measured current. From READ_IOUT register.
|
||
|
curr[1-12]_max Maximum current. From IOUT_OC_WARN_LIMIT register.
|
||
|
curr[1-12]_lcrit Critical minimum output current. From IOUT_UC_FAULT_LIMIT
|
||
|
register.
|
||
|
curr[1-12]_crit Critical maximum current. From IOUT_OC_FAULT_LIMIT register.
|
||
|
curr[1-12]_max_alarm Current high alarm. From IOUT_OC_WARNING status.
|
||
|
curr[1-12]_crit_alarm Current critical high alarm. From IOUT_OC_FAULT status.
|
||
|
|
||
|
For each attribute index, either voltage or current is
|
||
|
reported, but not both. If voltage or current is
|
||
|
reported depends on the chip configuration.
|
||
|
|
||
|
temp[1-2]_input Measured temperatures. From READ_TEMPERATURE_1 and
|
||
|
READ_TEMPERATURE_2 registers.
|
||
|
temp[1-2]_max Maximum temperature. From OT_WARN_LIMIT register.
|
||
|
temp[1-2]_crit Critical high temperature. From OT_FAULT_LIMIT register.
|
||
|
temp[1-2]_max_alarm Temperature high alarm.
|
||
|
temp[1-2]_crit_alarm Temperature critical high alarm.
|
||
|
|
||
|
fan[1-4]_input Fan RPM.
|
||
|
fan[1-4]_alarm Fan alarm.
|
||
|
fan[1-4]_fault Fan fault.
|
||
|
|
||
|
Fan attributes are only available on chips supporting
|
||
|
fan control (UCD90124, UCD90910). Attribute files are
|
||
|
created only for enabled fans.
|
||
|
Note that even though UCD90910 supports up to 10 fans,
|
||
|
only up to four fans are currently supported.
|