Qualcomm Technologies, Inc. G-link QoS Configuration
Required properties:
-compatible : should be "qcom,glink-qos-config"
-qcom,flow-info : A table of MTU transmission time specific for a power state.
The total number of entries in the table should be equal to the
number of supported flows.
-qcom,mtu-size : The MTU size for which the qos elements are configured.
-qcom,tput-stats-cycle: The number of allowable cycles for a packet to be
transmitted without its priority being re-evaluated.
Example:
qcom,glink-qos-config-adsp {
compatible = "qcom,glink-qos-config";
qcom,flow-info = <0x80 0x0>,
<0x70 0x1>,
<0x60 0x2>,
<0x50 0x3>;
qcom,mtu-size = <0x800>;
qcom,tput-stats-cycle = <0xa>;
};